Испытание силы разрыва шприца: обеспечение производительности и безопасности шприца

The syringe break loose force test is a vital part of quality assurance for medical syringes, ensuring their proper functionality before use. This test measures the force required to move the plunger of a syringe from its resting position, also known as the “break loose” force. It is a critical test for verifying the ease of plunger movement, which directly affects the safety and usability of syringes, particularly in medical applications where precision and reliability are paramount. This article explores the importance of the syringe break loose force test, the standard testing procedures, and how to perform the test according to ISO 8537.

Break Loose Force Testing for Syringe Q

What is the Syringe Break Loose Force Test?

The syringe break loose force test measures the force required to initiate the movement of the syringe plunger, which is essential for assessing the ease of operation. The test is critical to ensure that syringes are easy to use, especially when filled with medication or fluid, without requiring excessive force that could cause difficulty for medical personnel or patients. The break loose force is typically measured in newtons (N), and the test is conducted using a mechanical testing machine.

In the test, the syringe is filled with a specified fluid (usually distilled water) up to a predetermined level (50% of the nominal capacity). A vertical downward force is applied to the syringe plunger until the plunger begins to move, indicating the initiation of movement. The force required to begin this movement is recorded, providing crucial data for evaluating the syringe’s mechanical functionality.

Why is the Syringe Break Loose Force Test Important?

This test is essential for several reasons:

  1. Safety and Comfort: Syringes must be easy to operate, especially when used in medical procedures. Excessive resistance in the plunger could lead to difficulty in administering medication.
  2. Compliance with Standards: The test ensures that syringes meet regulatory requirements and comply with industry standards such as ISO 8537, ISO 7886-1, and USP 382.
  3. Performance Validation: The break loose force test ensures that syringes are mechanically sound, helping prevent issues such as piston failure or leakage during use.

By performing this test, manufacturers can ensure that their syringes meet the necessary standards for patient safety and efficient use in medical procedures.

Break Loose Force Test: Test Procedure and Equipment

The procedure for conducting the syringe break loose force test involves the following steps:

  1. Preparing the Syringe:
    Fill the syringe with distilled water, ensuring it reaches 50% of its nominal capacity. This step simulates the conditions under which the syringe would be used in real medical settings.
  2. Setup:
    Secure the syringe to a suitable test stand. This stand is designed to hold the syringe steady while allowing the plunger to be tested. The needle is positioned downward to prevent any interference during testing.
  3. Force Application:
    Using a mechanical testing machine, apply a vertical downward force to the syringe’s plunger. Gradually increase the force until the plunger begins to move. The moment the plunger starts to move (i.e., the break loose force is reached), the test machine records the force applied.
  4. Recording Results:
    The force required to initiate movement, as well as the maximum force required to fully depress the plunger, are recorded and analyzed. This data helps determine if the syringe meets the required standards.

ISO 8537 and Glide Force Test for Syringe

The glide force test for syringe, as outlined in ISO 8537, focuses on evaluating the resistance experienced when the plunger is pushed through the syringe barrel. This test is similar to the break loose force test but extends beyond the initiation of movement to evaluate the overall friction encountered as the plunger moves.

ISO 8537 specifies the testing method and equipment necessary to conduct the glide force test. It ensures syringes exhibit consistent and predictable plunger movement, which is critical for efficient and safe usage. Adherence to ISO 8537 guarantees that syringes meet global standards for smooth operation and user safety.

Testing Equipment: MST-01 Medical Syringe Tester

For precise and reliable syringe break loose force testing, the MST-01 Medical Syringe Tester from Cell Instruments is a top-tier solution. This device is specifically designed for testing the forces related to syringe operation, including break loose and glide forces, and other critical measurements like plunger pull-out force and syringe sliding resistance.

Key Features:

  • High Precision: The MST-01 offers accurate force measurements with a precision of 0.5% of full scale, ensuring reliable results.
  • Customizable Test Programs: Users can design test programs tailored to specific requirements, making it a versatile tool for various syringe testing applications.
  • Compliance with Standards: The MST-01 conforms to ISO 8537, USP 382, and other international standards, making it suitable for quality testing in regulated industries.
  • Ease of Use: With a 7-inch HMI touch screen and automated test cycles, the MST-01 simplifies testing procedures, improving efficiency and consistency in results.

The syringe break loose force test is a fundamental procedure in ensuring the quality and safety of syringes used in medical and pharmaceutical applications. By following standardized procedures like those outlined in ISO 8537 and utilizing advanced testing equipment like the MST-01 Тестер медицинских шприцев, manufacturers can ensure their products meet regulatory requirements and provide optimal performance. This test not only safeguards patient safety but also enhances the usability of syringes in various medical procedures.

FAQ

  1. What is the purpose of the syringe break loose force test?
    The break loose force test measures the force required to initiate movement of the syringe plunger, ensuring that the syringe operates smoothly and safely.
  2. What equipment is required for syringe break loose force testing?
    A mechanical testing machine, force gauge, and suitable clamps or test stands are needed for accurate testing.
  3. How does the glide force test differ from the break loose force test?
    The glide force test evaluates the resistance experienced during the entire plunger movement, while the break loose force test measures only the force required to initiate movement.
  4. What standards govern syringe break loose force testing?
    ISO 8537 and USP 382 are commonly used standards that outline the procedures and requirements for syringe testing.
  5. How can the MST-01 Medical Syringe Tester help in testing?
    The MST-01 offers precise force measurements and supports multiple test programs, ensuring syringes meet industry standards and operate reliably.

Related Product

Syringe Plunger Glide Force Tester

Related Article

Syringe Breakaway Force Testing

Syringe Glide Force Testing

Syringe Plunger Glide Force Test

Syringe Piston Glide Force Test

Syringe Push Force Tester

Syringe Compression Force

Reference

USP 382

ISO 7886-1

ISO 8537

ISO 11040-4

ISO 11608-5

Корзина
ru_RUРусский

Нужен метод тестирования или ценовое предложение.

Оставьте нам сообщение, и мы ответим как можно скорее!